BTYDX - SOLUTION S0613 ST-1

  • MSDS: BTYDX
  • Manufacturer: NALCO CHEMICAL COMANY
  • Product Name: SOLUTION S0613 ST-1
  • National Stock Number: 6810-00N047712
Product Identification

Product ID:SOLUTION S0613 ST-1
MSDS Date:08/03/1992
FSC:6810
NIIN:00N047712
MSDS Number: BTYDX

Responsible Party
NALCO CHEMICAL COMANY
ONE NALCO CENTER
NAPERVILLE, IL 60563-1198
US

Emergency Phone: 708-920-1510(24 HOURS)

Info Phone: 708-305-1000

Preparer: RICKY A. STACKHOUSE

Cage: 89524

Contractor
ONDEO NALCO COMPANY
NAPERVILLE, IL 60563-1198 US

Telephone: (630) 305-1000

Cage: 89524

Ingredients

SULFAMIC ACID

CAS: 5329-14-6

RTECS: WO5950000

Fraction By Weight: 95-100%

OSHA PEL N/K

ACGIH TLV: N/K


CORN STARCH

CAS: 9005-25-8

RTECS: GM5090000

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT:CORROSIVE W/POSSIBLE
PERMANENT DAMAGE DEPENDING ON LENGTH OF EXPOSURE & ON FIRST AID
ACTION GIVEN. SKIN CONTACT:CORROSIVE, POSSIBLY RESULTING IN THIRD
DEGREE BURNS DEPENDING ON LENGTH OF E XPOSURE & ON FIRST AID ACTION
GIVEN. INHAL:CAN CAUSE SEVERE RESPIRATORY IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:A REVIEW OF AVAILABLE DATA DOES NOT IDENTIFY
ANY SYMPTOMS FROM EXPOSURE NOT PREVIOUSLY MENTIONED.
Medical Cond Aggravated by Exposure:A REVIEW OF AVAILABLE DATA DOES NOT
IDENTIFY ANY WORSENING OF EXISTING CONDITIONS.

First Aid

First Aid:EYE:IMMED FLUSH FOR AT LST 15 MINS WHILE HOLDING EYELIDS
OPEN. CALL MD AT ONCE. SKIN:IMMED FLUSH W/WATER FOR AT LST 15 MINS.
FOR LG SPLASH, FLOOD BODY UNDER SHOWER. CALL MD AT ONCE. INGEST:DO
NOT INDU CE VOMIT. GIVE WATER. CALL MD. CAUTION:IF UNCON, HAVING
TROUBLE BRTHG/IN CONVLS, DO NOT INDUCE VOMIT/GIVE WATER.
INHAL:REMOVE TO FRESH AIR. TREAT SYMPS. CALL MD. NOTE TO MD:BASED
ON INDIVIDUAL(SUPDAT)

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY EVOLVE SO*X UNDER FIRE CONDITIONS.

Accidental Release

Spill Release Procedures:SOLID SPILLS:SWEEP OR VACUUM UP & RECLAIM INTO
RECOVERY/SALVAGE DRUMS FOR DISPOSAL. WEAR PROTECTIVE EQUIPMENT
SPECIFIED IN PERSONAL PROTECTION EQUIPMENT SECTION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CAUSES EYE INJURY & SKIN IRRITATION.
DO NOT GET IN EYES. AVOID CONTACT W/SKIN & CLOTHING. AVOID
BREATHING DUST. DO NOT TAKE INTERNALLY.
Other Precautions:DO NOT BREATHE SMOKE OR FUMES.

Exposure Controls

Respiratory Protection:RESPIRATORY PROTECTION IS NOT NORMALLY NEEDED
DUE TO IT PHYSICAL FORM. FOR LARGE SPILLS, ENTRY INTO LARGE TANKS,
VESSELS OR ENCLOSED SMALL SPACES W/INADEQ VENT, A NIOSH/MSHA
APPROVED PRESSURE DEMAND S CBA IS RECOMMENDED.
Ventilation:IF SIGNIFICANT DUSTING OCCURS, LOCAL EXHAUST VENTILATION IS
RECOMMENDED.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPVD CHEMICAL SPLASH GOGGLES (FP N
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER MTG ANSI
DSGN CRITERIA . WEAR SUITABLE PROTECTIVE EQUIPMENT.
Work Hygienic Practices:IF CLOTHING IS CONTAMINATED, REMOVE CLOTHING &
THORO WASH THE AFFECTED AREA. LAUNDER CONTAMINATED CLTHG BEFORE
REUSE.
Supplemental Safety and Health
PH:1.2(AT 1%). FIRST AID PROC:RXNS OF PATIENT, MD'S JUDGMENT SHOULD BE
USED TO CONTROL SYMPS & CLINICAL CNDTN. PROBABLE MUCOSAL DMG MAY
CONTRAINDICATE USE OF GASTRIC LAVAGE. MEASURES AGAINST CIRCULATO RY
SHOCK, RESPIRATORY DEPRESSION & CONVULSIONS MAY BE NEEDED.

Chemical Properties

HCC:N1
pH:SUPDAT
Solubility in Water:PARTIALLY
Appearance and Odor:OFF-WHITE CRYSTALS; NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG BASES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN THE EVENT OF COMBUSTION CO, CO*2,
SO*X, NH*3 MAY BE FORMED. DO NOT BREATHE SMOKE/FUMES.

Disposal

Waste Disposal Methods:IF THIS PROD BECOMES A WASTE, IT MEETS CRITERIA
OF HAZ WASTE AS DEFINED UNDER RCRA 40 CFR 261. HAZ WASTE D002. AS
HAZ SOLID WASTE, IT MUST BE DISP OF IN LICENSED HAZ WASTE
TREATMENT, STOR & DISP FACIL ITY I/A/W LOC, STATE & FED REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.